Factory
Capacity
20TPH
Client
Factory
Supply
October 2009
System Description
The treatment process is comprised of:
Pre-treatment by media filtration
Reverse osmosis membranes for desalination of brackish water
Remineralization
Post-chlorination disinfection
Recovery of media filter backwash water to minimize waste disposal to evaporation ponds
The system meets all local water quality requirements and is now being operated and monitored by the local council.